Code: C-1304
Classification: LS (1st tandem): LS abnormality
Cause:
An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Motor cooling fan motor (FM4)
- LS control board (LSCB)
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality.
- Rotate the fan by hand, and repair or replace it when there is any abnormality. (Wiring diagram: LS-505: 7-H, LS-506: 6-H).
- Replace FM4.