Code: C-1307
Classification: LS (2nd tandem): LS abnormality
Cause:
An error detection signal is detected continuously for a specified period of time while the paper cooling fan/1 (FM2) is ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper cooling fan motor /1 (FM2)
LS control board (LSCB)
Correction:
The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality.
Rotate the fan or I/O by hand, and repair and replace it if an abnormality is found. (Wiring diagram: LS-505: 6-H, LS-506: 5-H).
Replace FM2 or FM6.
Replace LSCB.