Error code C-1318 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1318
ClassificationLS (3rd tandem): LS abnormality
Cause:

An error detection signal is detected continuously for a specified period of time while the paper cooling fan /Mi (FM3) is ON. (LS-505) An error detection signal of FM6 is detected continuously for a specified period of time while the paper cooling fan/2 (FM6) is ON. (LS-506)

Measures to take when alert occurs:

         The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • Paper cooling fan motor /Mi (FM3) (LS-505)
  • paper cooling fan motor/2 (FM6) (LS-506)
  • LS control board (LSCB)
Correction:      
Note: 
  • The message "Please call service" is displayed on the panel.

Solution:

  1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality.
  2. Rotate the fan or I/O by hand, and repair and replace it if an abnormality is found. (Wiring diagram: LS-505: 5-A, LS-506: 5-H). 
  3. Replace FM3 (LS-505).
  4. Replace FM6 (LS-506).
  5. Replace LSCB.
Back to blog