Code: C-1332
Classification: PB: PB abnormality
Cause:
An rotation error detection signal is detected continuously for a specified period of time while the exhaust fan /1 (FM80) is started or driving.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
PB control board (PBCB)
PB drive board (PBDB1)
Exhaust fan/1 (FM80)
Correction:
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note:
When you isolate the faulty part, the limited use is available.
The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Check the connector connection and the wiring between PBDB1 and the fan, and repair it when there is any abnormality.
Rotate the fan or I/O by hand, and repair it when there is any abnormality. (Wiring diagram: PB-503: 3-D, 19-U).
Replace FM80.
Replace PBDB1.
Replace PBCB.