Code: C-1364
Classification: RU: RU-509 abnormality
Cause:
An error detection signal of FM14 is detected continuously for a specified period of time while the humidification section paper fan (FM14) is ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Power supply fan (FM14)
- DC power supply (DCPS)
Turn OFF/ON the sub power switch (SW2) on the main body when releasing an abnormal condition.
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between DCPS and the fan, and repair it if any abnormality.
- Check the connector connection and the wiring between HMDB and RUCB, and repair it if any abnormality.
- Rotate the fan by hand, and repair it if there is any abnormality. (Wiring diagram: RU-509: 6-I).
- Replace FM14.
- Replace DCPS.