Code: C-1404
Classification: SD: SD-513 abnormality
 Cause:

 Non-volatile memory abnormality.

 Measures to take when alert occurs:

         The main body and the option stop immediately.                                       
Estimated abnormal parts:
  • SD control board (PCB1)
Correction: 
       Note: 
  • The message "Please call service" is displayed on the panel. 

Solution:

  1. Deactivate the sub power switch and unplug the power plug. Restart the main body after 10 seconds.
  2. Check the connector connection and the wiring of PCB1, and if there is any abnormality, repair them..
  3. Reinstall the SD firmware.
  4. Replace PCB1.