Error code C-1515 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1515
ClassificationPB: PB abnormality
Cause:
The glue tank movement operation has not been completed within a specified period of time after the glue tank movement motor (M31) becomes active.
 
 Measures to take when alert occurs:
         The main body and the option stop immediately.                                       
Estimated abnormal parts:
  • PB control board (PBCB)
  • PB drive board (PBDB1)
  • Glue tank movement motor (M31)
Correction: 
         Press the help key to activate and deactivate the sub power switch (SW2) of the main body.          
      Note: 
  • When you isolate the faulty part, the limited use is available.
  • The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
  • When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution:
  1. Check the glue tank movement section, and clean or repair it when there is any abnormality.
  2. Check the connector connection and the wiring between PBDB1 and the motor, and repair it when there is any abnormality.
  3. Check the connector connection and the wiring between PBDB1 and PBCB, and repair it when there is any abnormality.
  4. Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: PB-503: 8-D)
  5. Replace M31.
  6. Replace PBDB1.
  7. Replace PBCB.
Back to blog