Error code C-1524 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1524
Classification: PB: PB abnormality
Cause:
The cover paper table up or down movement start has not been completed within a specified period of time after the cover paper table up down motor/Fr (M46) becomes active.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
PB control board (PBCB)
PB drive board (PBDB1)
Cover paper table up down motor/Fr (M46)
Correction:
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note:
When you isolate the faulty part, the limited use is available.
The message "Please call service" and "Press [Help] to disengage" are displayed alternately on the touch panel.
When you press the help key, the message "Please turn on power again" is displayed on the touch panel.
Solution:
Check the cover paper table up down section, and clean or repair it when there is any abnormality.
Check the connector connection and the wiring between PBDB1 and the motor, and repair it when there is any abnormality.
Check the connector connection and the wiring between PBDB1 and PBCB, and repair it when there is any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: PB-503: 11-D)