Error code C-1546 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1546
ClassificationPB: PB abnormality
Cause:
When the prescribed temperature is obtained and after the glue tank heater (H1) becomes active, temperature that the glue apply roller temperature sensor (TH1) detects has not risen to a prescribed level within a specified period of time.
 Measures to take when alert occurs:
         The main body and the option stop immediately.                                       
Estimated abnormal parts:
  • AC drive board (ACDB)
  • Glue tank heater (H1)
  • Glue apply roller heater (H2)
  • PB control board (PBCB)
  • PB drive board (PBDB1)
  • Glue apply roller motor (M32)
  • Glue apply roller temperature sensor (TH1)
Correction: 
         Warning
  • Be sure to select the DIPSW3-1 to 0 after you replace the defective parts. If DIPSW3-1 is selected to 0 before defective parts are fixed, it possibly cause a fire.        
      Note: 
  • The message "Please call service" is displayed on the panel.
Solution:
  1. Check the glue apply heater, and clean or repair it when there is any abnormality.
  2. Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it when there is any abnormality.
  3. Check the connector connection and the wiring between ACDB and the heater, and repair it when there is any abnormality.
  4. Check the installation conditions of the heater and the temperature sensor, and repair or replace it when there is any abnormality. (Wiring diagram: PB-503: 27-Q, 9-U)
  5. Replace TH1.
  6. Replace H2.
  7. Replace ACDB.
  8. Replace PBCB.