Error code C-1555 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1555 Classification: PB: PB abnormality Cause: After warming-up is completed, the glue apply roller temperature sensor (TH1) detects an abnormal low temperature.   M...
Read More

Error code C-1554 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1554 Classification: PB: PB abnormality Cause: The glue tank temperature sensor/Lw (TH4) detects an abnormal high temperature (hardware) TH4 detects an abnormal high ...
Read More

Error code C-1553 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1553 Classification: PB: PB abnormality Cause: The glue tank temperature sensor/Md (TH3) detects an abnormal high temperature (hardware) TH3 detects an abnormal high ...
Read More

Error code C-1552 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1552 Classification: PB: PB abnormality Cause: The glue tank temperature sensor/Up (TH2) detects an abnormal high temperature (hardware) TH2 detects an abnormal high...