Error code C-1205 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1205 Classification: LS (1st tandem): LS abnormality Cause: The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operat...
Read More

Error code C-1204 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1204 Classification: LS (1st tandem): LS abnormality Cause: The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after after the gri...
Read More

Error code C-1203 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1203 Classification: LS (1st tandem): LS abnormality Cause: The alignment plate home sensor (PS12) does not turn ON within a specified period of time after after the al...
Read More

Error code C-1202 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1202 Classification: LS (1st tandem): LS abnormality Cause: The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit mo...