Code: C-0119
Classification: Main body: Drive
Cause:
The transfer belt cleaning motor (M5) speed abnormality.
The M5EM error detection signal is detected twice in succession within a specified period of time after M5 was turned ON.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- Transfer belt cleaning motor (M5).
- Printer control board (PRCB).
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality.
- Check the I/O drive and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 20-P)
- Replace M5
- Replace PRCB