Code: C-0161
Classification: PF: Power abnormality
Cause:
Abnormality of the power for the PF conveyance motor (M3) inside the PF drive board (PFUDB) of the 3rd tandem PF-703.
An error detection signal (blowout of ICP) of M3 is detected when the M3 is activated.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- PF exit conveyance motor (M3: PF-703)
- PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, repair/ replace it if any abnormality and then replace the PFUDB (Wiring diagram: PF-703: 8-L).
- Replace M3 and PFUDB at a time.