Error code C-0207 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0207
 Classification: Main body: Tray2
Cause: 
Tray2 up abnormality 2.
When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift up motor /2 (M34) turns ON after lifting operation. At this time, an error detection signal is not detected.                                                                                                          
Measures to take when alert occurs:                                                              
The main body and the option stop immediately.                                               
Estimated abnormal parts:
  • Upper limit sensor /2 (PS10)
  • Tray lift-up motor /2 (M34)
  • Printer control board (PRCB)
  • DC power supply /2 (DCPS/2)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition                                                                                                  
Note: "Please call service" is displayed on the touch panel.                                         
Solution:   
  1. Check the paper loaded condition and the rear end restriction plate condition of the tray2, and repair it if any abnormality.                                                                                                          
  2. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality.
  3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 21-A).
  4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body: (2/4): 18-A)
  5. Replace PS10
  6. Replace M34
  7. Replace PRCB
  8. Replace DCPS /2
Back to blog