Code: C-0207
Classification: Main body: Tray2
Cause:
Tray2 up abnormality 2.
When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift up motor /2 (M34) turns ON after lifting operation. At this time, an error detection signal is not detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Upper limit sensor /2 (PS10)
- Tray lift-up motor /2 (M34)
- Printer control board (PRCB)
- DC power supply /2 (DCPS/2)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition
Note: "Please call service" is displayed on the touch panel.
Solution:
- Check the paper loaded condition and the rear end restriction plate condition of the tray2, and repair it if any abnormality.
- Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 21-A).
- Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body: (2/4): 18-A)
- Replace PS10
- Replace M34
- Replace PRCB
- Replace DCPS /2