Error code C-0212 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0212
 Classification: PF: Tray 10
Cause: 
3rd tandem PF-703 middle tray lift abnormality.
When the upper limit sensor/2 (PS9) is inactive, PS9 does not become active within 20 seconds after the paper lift motor/2 (M8) started the lifting operation. Alternatively, the paper suction sensor/Fr2 (PS27) and the paper suction sensor/Rr2 (PS28) become active before PS9 becomes active while the tray lifts.
                                                                                                      
Measures to take when alert occurs:                                                              
The main body and the option stop immediately.   
                                            
Estimated abnormal parts:
  • Upper limit sensor /2 (PS9: PF-703)
  • Paper lift motor /2 (M8: PF-703)
  • PF drive board (PFUDB: PF-703/706)
Correction: 
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.                                                                                                  
Note: "Please call service" is displayed on the touch panel.                                         
Solution:    
  1. Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality.               
  2. Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality.
  3. Check the I/O drive of the motor and the coupling of the gear, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 12-F).
  4. Check the I/O and the operation of the sensor, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 9-F)
  5. Replace PS9
  6. Replace M8
  7. Replace PFUDB
Back to blog