Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-0214 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-0214
Classification:PF: Tray 11
Cause:
3rd tandem PF-703 lower tray up abnormality.
When the upper limit sensor/3 (PS13) is inactive, PS13 does not become active within 20 seconds after the paper lift motor/3 (M9) started the lifting operation. Alternatively, the paper suction sensor/Fr3 (PS29) and the paper suction sensor/Rr3 (PS30) become active before PS13 becomes active while the tray lifts.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Upper limit sensor /3 (PS13: PF-703)
Paper lift motor /3 (M9: PF-703)
PF drive board (PFUDB: PF-703)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the touch panel.
Solution:
Check the paper loaded condition and the rear end restricted plate misaligned of the lower tray, and repair it if any abnormality.
Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 19-F).
Check the I/O and the operation of the sensor, and repair or replace it if there is any abnormality. (Wiring diagram: PF-703: 16-F).