Error code C-0384 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-0384
Classification: PF: Fan abnormality
Cause:
2nd tandem PF-703 cooling fan rotation abnormality 2.
The FM21EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
                     

 Measures to take when alert occurs:                                                                      

The main body and the option stop immediately.                                                 

Estimated abnormal parts:

  • PF cooling fan /3 (FM21: PF-703)
  • PF drive board (PFUDB)

Correction:

Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.

Note: The message "Please call service" is displayed on the panel.                      
Solution:
  1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
  2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 23-F).
  3. Replace FM21 and PFUDB.                                                                                                                                                          