Code: C-0389
Classification:PI-PFU: Fan abnormality
Cause:
PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) power abnormality.
The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper feed assist fan /Fr2 (FM5: PF-703)
Paper feed assist fan /Fr2 (FM3: PF-706)
PF drive board (PFUDB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality.
Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: (PF-703: 10-F, PF-706: 7-C).
Replace FM5 and PFUDB at a time: PF-703 Replace FM3 and PFUDB at a time: PF-706