Code: C-1105
Classification: FS: FS-532 abnormality
Cause:
The paper exit opening unit does not get to the specified opening position within a specified period of time after the paper exit opening motor (M10) starts operation.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- FNS control board (FNSCB)
- Paper exit opening motor (M10)
- Paper exit home sensor (PS13)
Correction:
Turn OFF/ON the sub power switch (SW2) of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
- Check the paper exit opening section, and clean/repair it if any abnormality.
- Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality.
- Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 3-F)
- Check the I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 4-B)
- Replace PS13.
- Replace M10.
- Replace FNSCB.