Error code C-1132 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1132
Classification: PK: PK abnormality
Cause:
The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
FNS control board (FNSCB)
Punch drive board (PDB)
Punch motor (M301)
Punch home sensor /1 (PS301)
Punch home sensor /2 (PS307)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the punch kit, and clean/repair it if any abnormality.
Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality.
Check the connector connection and the wiring between FNSCB and PDB, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PK: 5-B)
Check I/O and the operation of the sensor, and repair/replace it if any abnormality.
Replace M301.
Replace PS301 and PS302.
Replace PDB.
Replace FNSCB.
July 17 2024
sherlyn planas