Error code C-1132 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1132
Classification: PK: PK abnormality
Cause:
The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON.
   
Measures to take when alert occurs:
The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • FNS control board (FNSCB)
  • Punch drive board (PDB)
  • Punch motor (M301)
  • Punch home sensor /1 (PS301)
  • Punch home sensor /2 (PS307)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
                      
Solution:
  1. Check the punch kit, and clean/repair it if any abnormality.
  2. Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality.
  3. Check the connector connection and the wiring between FNSCB and PDB, and repair it if any abnormality.
  4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PK: 5-B)
  5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 
  6. Replace M301.
  7. Replace PS301 and PS302.
  8. Replace PDB.
  9. Replace FNSCB. 
Back to blog