Shipping cutoff time is 3pm EST - Orders received after 3pm will be shipped out the following business day(Mon-Friday)Call Us: (800) 675 7821 - From 9:00 am EST to 5:00 pm EST(Mon-Friday)
Error code C-1133 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1133
Classification: ZU: ZU-608 abnormality
Cause:
The punch shift home sensor (PS605) does not turn ON even after a specified period of time after the punch shift motor (M605) starts the home position search operation.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
ZU control board (ZUCB)
Punch shift motor (M605)
Punch shift home sensor (PS605)
Correction:
Turn OFF/ON the sub power switch of the main body.
Note: The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between ZUCB and motor/sensor, and repair it if any abnormality.
Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 1-B)
Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 4-B).