Code: C-1275
Classification: SD: SD-506 abnormality
Cause:
The wire slack sensor (PS66) detected the slack of the trimmer edge drive wire.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Wire slack prevention sensor (PS66)
- SD control board (SDCB)
- SD drive board (SDDB)
Press the help key to activate and deactivate the sub power switch (SW2) of the main body.
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the wire slack, and repair the trimmer blade when there is any abnormality.
- Check the connector connection and the wiring between SDCB and the sensor, and repair it when there is any abnormality.
- Check I/O and the operation of the sensor, and repair or replace it when there is any abnormality. (Wiring diagram: SD-506: 10-U).
- Replace PS66..
- Replace SDCB.