Code: C-1275
Classification: SD: SD-513 abnormality
Cause:
While the trimmer blade motor (M31) performs the home position search or during the trimmer operation, the wire slack prevention sensor (PS55) becomes active.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Wire slack prevention sensor (PS55)
- SD control board (PCB1)
Press help key and activate and deactivate the sub power switch (SW2) of the main body.
Note:
- Faulty part isolation allows you to use the machine temporarily.
- When you press HELP key, the message "Please call service" and "Press [Help] to disengage" are alternately displayed.
- When you press HELP key, the message "Please turn on power again" is displayed.
Solution:
- Check the trimmer blade section, and if there is any abnormality, clean or repair it.
- Check the connector connection and the wiring harness between PCB1 and the sensor. Then, repair them when there is any abnormality. (Wiring diagram: SD-513 (2/2): 11-O).
- Check I/O and the operation of the sensor, and if there is any abnormality, repair or replace it.
- Replace the trimmer blade drive wire.
- Replace PS55.
- Replace PCB1.