Error code C-1313 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1313
ClassificationSD: SD-513 abnormality
Cause:

A rotation error detection signal is detected continuously for a specified period of time while the fall assist fan/Fr (FM4) is started or driving. When the fan is stopping, no abnormality or stop signal are detected. 

Measures to take when alert occurs:

         The main body and the option stop immediately.                                                 
Estimated abnormal parts:
  • Fall assist fan/Fr (FM4)
  • SD drive board (PCB2)
  • SD control board (PCB1)
Correction: 
         Press the help key to  activate and deactivate the sub power switch (SW2) of the main body.  
    Note: 
  • Faulty part isolation allows you to use the machine temporarily.
  • When you press help key, the messages "Please call service" and "Press [Help] to disengage" are alternately displayed .
  • When you press the help key, the message "Please turn on power again" is displayed.           

Solution:

  1. Check the connector connection and the wiring harness between PCB2 and the fan. Then,  repair them when there is any abnormality. (Wiring diagram: SD-513 (1/2): 4-N).
  2. Check the connector connection and the wiring harness between PCB2 and PCB1, and of there is any abnormality, repair them.
  3. Rotate the fan or I/O by hand, and repair or replace it when there is any abnormality. 
  4. Replace FM4.
  5. Replace PCB2.
  6. Replace PCB1.