Error code C-1316 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951
Code: C-1316
Classification: LS (3rd tandem): LS abnormality
Cause:
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
Paper cooling fan motor /Fr (FM1)
LS control board (LSCB)
Correction:
The message "Please call service" is displayed on the panel.
Solution:
Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality.
Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 4-A).
Replace FM1.
Replace LSCB.