Code: C-1351
Classification: RU: RU-509 abnormality
Cause:
Error detection signals of FM/1, FM/2 and FM/3 are detected continuously for a specified period of time while the entrance paper fans/1 (FM1), /2 (FM2), /3 (FM3) are ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Entrance paper fan /1 (FM1)
- Entrance paper fan /2 (FM2)
- Entrance paper fan /3 (FM3)
- RU control board (RUCB)
Turn OFF/ON the sub power switch (SW2) on the main body when releasing an abnormal condition.
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality.
- Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 8-F, 9-F).
- Replace FM1, FM2 and FM3.
- Replace RUCB.