Code: C-1352
Classification: RU: RU-509 abnormality
Cause:
Error detection signals of FM4 and FM5 are detected continuously for a specified period of time while the ventilation assist fans/1 (FM4) and /2 (FM5) are ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Ventilation assist fan /1 (FM4)
- Ventilation assist fan /2 (FM5)
- RU control board (RUCB)
Turn OFF/ON the sub power switch (SW2) on the main body when releasing an abnormal condition.
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality.
- Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 9-F, 8-H).
- Replace FM4 and FM5.
- Replace RUCB.