Code: C-1354
Classification: RU: RU-509 abnormality
Cause:
Error detection signals of FM18, FM19 and FM20 are detected continuously for a specified period of time while the entrance paper fans/7 (FM18), /8 (FM19) and /9 (FM20) are ON.
Measures to take when alert occurs:
The main body and the option stop immediately.
Estimated abnormal parts:
- Entrance paper fan /7 (FM18)
- Entrance paper fan /8 (FM19)
- Entrance paper fan /9 (FM20)
- RU control board (RUCB)
Turn OFF/ON the sub power switch (SW2) on the main body when releasing an abnormal condition.
Note:
- The message "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality.
- Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 18-L).
- Replace FM18, FM19 and FM20.
- Replace RUCB.