Solutions

Error code C-1255 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1255 Classification: SD: SD-506 abnormality Cause: The clincher up down home sensor (PS26) does not become active within a specified period of time after the clincher u...
Read More

Error code C-1254 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1254 Classification: SD: SD-513 abnormality Cause: After the 2nd folding knife motor (M14) starts the home position search operation, the 2nd folding knife home sensor/...
Read More

Error code C-1254 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1254 Classification: SD: SD-506 abnormality Cause: The 2nd folding blade home sensor/2 (PS23) does not become active within a specified period of time after the 2nd fol...
Read More

Error code C-1253 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1253 Classification: SD: SD-513 abnormality Cause: After the 1st folding knife motor (M13) starts the home position search operation, the 1st folding knife home sensor/...
Read More