Error code C-1260 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1260 Classification: SD: SD-506 abnormality Cause: The guide shaft home sensor (PS46) does not become active even after a specified period of time after the guide shaft...
Read More

Error code C-1259 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1259 Classification: SD: SD-513 abnormality Cause: After the booklet set motor (M20) starts the home position search operation, the booklet set unit position sensor (PS...
Read More

Error code C-1259 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1259 Classification: SD: SD-506 abnormality Cause: The bundle press home sensor (PS35) does not become active within a specified period of time after the bundle press s...
Read More

Error code C-1258 for Bizhub Press 1250 1250P 1052 Bizhub Pro 951

Code: C-1258 Classification: SD: SD-513 abnormality Cause: After the clamp motor (M37) starts the home position search operation, the clamp open close home sensor (PS31) does n...
Read More