Code: C-0115
Classification: Main body: Power abnormality
Cause:
Abnormality 1 of the SD/CL_24V power for the printer control board (PRCB) vertical conveyance.
At the start, the error detection signals of the PRCB vertical conveyance solenoid/clutch ICP blowout and 24V cut off are detected.
Measures to take when alert occurs: The main body and the option stop immediately.
Estimated abnormal parts:
- DC power supply /2 (DCPS/2)
- Printer control board (PRCB)
Correction:
Turn OFF/ON the power switch (SW2) of the main body when releasing an abnormal condition.
Note: "Please call service" is displayed on the panel.
Solution:
- Check the connector connection and the wiring related to DC24V between PRCB and DCPS /2, and repair it if any abnormality.
- Replace DCPS /2
- Replace PRCB