Solutions

Error code C-0398 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0398 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of...

Read more →

Error code C-0398 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0398 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of...

Error code C-0397 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0397 Classification: PI-PFU: Fan abnormality   Cause: PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of...

Read more →

Error code C-0397 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0397 Classification: PI-PFU: Fan abnormality   Cause: PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of...

Error code C-0396 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0396 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period...

Read more →

Error code C-0396 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0396 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period...

Error code C-0395 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0395 Classification: PI-PFU: Fan abnormality   Cause: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The EM error detection signal of FM10 is detected twice in succession within...

Read more →

Error code C-0395 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0395 Classification: PI-PFU: Fan abnormality   Cause: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The EM error detection signal of FM10 is detected twice in succession within...

Error code C-0394 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0394 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period...

Read more →

Error code C-0394 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0394 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period...

Error code C-0393 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0393 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality. The FM9EM error detection signal is detected twice in succession within a specified period...

Read more →

Error code C-0393 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0393 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality. The FM9EM error detection signal is detected twice in succession within a specified period...

Error code C-0392 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0392 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period...

Read more →

Error code C-0392 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0392 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period...

Error code C-0391 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0391 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period...

Read more →

Error code C-0391 for Bizhub Press 1250 1250P 1...

sherlyn planas

Code: C-0391 Classification: PI-PFU: Fan abnormality Cause: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period...